Summer rotation is open. Servicing slots for split and cassette units are being scheduled through to late March. Request a visit →
Nola Isle Aircon servicing
Sunlit living room with pale walls, a low sofa and a wall-mounted air conditioning unit running above it

Servicing bulletin · Issue 14

Cold air, quiet rooms, and a service record you can read.

Nola Isle services split, cassette, ducted and window units for homes and small premises. Every visit ends with a written condition report — what was cleaned, what was measured, and what to watch before the next one.

  • 01General servicing and full chemical overhaul
  • 02Split, cassette, ducted and window units
  • 03Written condition report after every visit

What we do

Five service lanes, priced by the job in front of us.

Pick the lane that matches the symptom. If you are not sure, book a diagnosis visit and we will tell you which one the unit actually needs rather than selling the largest package.

01

General servicing

Routine upkeep for a unit that still cools properly. Filters, blower wheel and evaporator face are cleaned in place, the drain line is flushed, and airflow and drainage are checked before we close the casing.

  • Typical time45–60 min per unit
  • CadenceEvery 3 months
  • Best forUnits cooling normally

02

Chemical overhaul

For units with a stubborn smell, a blocked drain, or a coil that no longer responds to surface cleaning. The fan coil is dismounted, the coil and blower are chemically treated and rinsed off-wall, and the drain pan is cleared before reassembly and a wet test.

  • Typical time2–3 hrs per unit
  • CadenceEvery 12–24 months
  • Best forOdour, slime, weak flow

03

Refrigerant check and top-up

Pressures are read at the service port and compared against the unit's rated range, joints and flares are leak-tested, and insulation is inspected. A unit that loses charge twice in a year has a leak, not a shortage — we locate and quote the repair instead of refilling it again.

  • Typical time60–90 min
  • CadenceAs required
  • Best forCooling that fades

04

Fault diagnosis

A single booked visit to find the cause: error codes read at the board, capacitor and contactor tested, sensors and thermistors checked, condenser fan and compressor behaviour observed under load. You get the finding in writing with the repair options ranked by cost.

  • Typical time60 min
  • CadenceOne-off
  • Best forTrips, codes, no cooling

05

Installation and relocation

New units mounted, existing units moved between rooms or properties. Includes bracket and gradient setting, pipe run and drainage planning, vacuum before charging, and a commissioning run with temperature readings at the vent.

  • Typical timeHalf day upwards
  • CadenceProject
  • Best forNew rooms, moves

How often

A servicing schedule that follows the hours, not the calendar.

Runtime and air quality decide the interval. Use the row that matches how the unit is actually used, then adjust if the room is dusty, near a kitchen, or close to a main road.

Recommended intervals for residential and small-premises units.
How the unit is used General service Chemical overhaul Watch for
Bedroom, nightly Every 3 months Every 18–24 months Musty smell on start-up
Living room, daily Every 3 months Every 12–18 months Dust streaks above the vent
Shop or studio, all day Every 2 months Every 12 months Drip marks on the wall
Kitchen-adjacent unit Every 2 months Every 9–12 months Greasy film on the louvres
Guest room, occasional Every 6 months Every 24–36 months Weak flow after long idle spells
Outdoor condenser, any unit Checked at each visit Coil rinse every 12 months Leaves packed against the fins

Between visits, rinse the washable filters every two to three weeks and let them dry fully before refitting. A damp filter is the most common cause of the smell people book an overhaul for.

Field notes

What the unit is telling you.

Six symptoms we are called out for most often, with the usual cause and what a technician checks first.

Airflow feels weak even on the highest fan speed

Usual cause — a loaded filter or a blower wheel caked with dust, which slows the air before it reaches the room.

We check — filter condition, blower wheel and evaporator face, then vent temperature against return-air temperature to confirm the split is in range.

Water dripping from the indoor unit

Usual cause — a blocked condensate drain or a drain pan that has lost its fall, so water backs up and spills over the lip.

We check — drain line clearance, pan gradient, unit level at the bracket, and whether the insulation on the pipe run has gone hard and started sweating.

A burning or hot-dust smell when it starts

Usual cause — dust burning off after a long idle period, which clears in minutes. If it persists, it points at electrical heat.

We check — terminal block and connections for discoloration, capacitor condition, fan motor draw, and the board for scorch marks. Switch the unit off at the isolator if the smell is sharp or acrid rather than dusty.

Ice forming on the pipe or coil

Usual cause — restricted airflow or low refrigerant charge, both of which drop the coil below freezing and let condensation set as ice.

We check — airflow first, then operating pressures and a leak test across the flares and joints. Topping up a leaking system just moves the problem three months down the line.

The unit keeps cycling on and off

Usual cause — short-cycling from an oversized unit for the room, a thermistor reading the wrong temperature, or a condenser that cannot shed heat.

We check — sensor position and resistance, set-point and mode, condenser coil cleanliness, and clearance around the outdoor unit.

Running costs climbing with no change in use

Usual cause — a dirty coil making the compressor run longer for the same room temperature, or a set-point that has crept down over the season.

We check — both coils, refrigerant charge, fan speeds, and the temperature split at the vent. A clean system reaching set-point quickly runs for less time, which is where the saving comes from.

On the day

How a visit runs.

Four steps, the same order every time, so nothing is skipped when the schedule is tight.

  1. Confirm and prepare

    We confirm your window the day before and tell you what to clear — roughly a metre of floor space beneath each unit and access to the isolator.

  2. Inspect before touching

    Readings are taken while the unit is still running as you left it: vent temperature, airflow, noise, drainage and error history. That baseline goes in the report.

  3. Service and protect

    Sheeting and a catch bag go up before any cleaning starts. Work follows the lane you booked, and anything outside it is quoted before it is carried out — never mid-job.

  4. Test, tidy and report

    A full cooling cycle is run to verify drainage and temperature split. We clear the site and send the written condition report with the next recommended interval.

Technician in a light shirt taking readings and writing notes beside diagnostic equipment
Readings are logged before and after the work so the report shows the change, not just the task list.

Request a visit

Tell us the symptom and the unit.

Send the details below and we will reply by email with the lane we would recommend, the time it needs, and the next available windows. No visit is booked until you confirm.

Reply time
Requests received before the evening are answered the same working day.
What to include
Unit type, roughly how old it is, and when you last had it serviced.
Scope we decline
Sealed commercial chiller plant and rooftop package units — we will say so rather than take the booking.
Cleaning equipment and coil treatment bottles laid out on a work surface before a chemical overhaul
Overhaul kit laid out before the fan coil comes off the wall.

Unit type, age and last service date help us size the visit correctly.

We reply by email with a recommended lane and available windows. Your details are used for this request only.